Model Object#
- class Model(**kwds)#
- Model class is a container for all objects of a simulation. - Parameters
- output – A string that defines the root name for all output files. 
- comment – A string that specifies a comment associated with the model. 
 
 - control(function, routine=None, script=None)#
- Defines a control command for one or more simulations. The execution of the command is deferred to CONSUB. - Parameters
- function (str) – The list of parameters that are passed to the user-defined subroutine. 
- routine (str) – - String containing the path of the DLL, followed by ‘::’ and the name of the Consub function. 
- A callable python function. 
 
- script (str) – Points to a file that contains the consub function defined in routine. 
 
 
 - generateOutput(visualize=False, timeout=None, verbosity_level=0)#
- Creates plt and animation h3d files. - Parameters
- visualize (bool) – If visualize argument is set to True, HyperView player is invoked and the h3d file of the model is loaded. 
- timeout (float) – A number indicating the time in seconds allowed for the execution. 
- verbosity_level (int) – - 0 - No output is printed to the screen. 
- 1 - Print only warnings to the screen. 
- 2 - Print all messages to the screen 
 
 
 
 - generate_abcd(pinput=None, poutput=None, returnResults=False)#
- Generate a state space representation of the model in the form of state matrices A, B, C, and D in the desired format. - Parameters
- Returns
- A dict of matrix names to values (‘a’, ‘b’, ‘c’, ‘d’, ‘e’) if returnResults is True. 
 
 - generate_eigensolution(nodamping=False, kinetic=False, returnResults=False)#
- Perform eigen-analysis of the model, generate eigenvalues and mode shapes. - Parameters
- nodamping (bool) – Ignores damping for all forces during the eigenvalue solution. 
- kinetic (bool) – Specifies whether the modal kinetic energy distribution is written out. 
- returnResults (bool) – Flag to indicate that EigenValue data is to be returned to the caller. 
 
- Returns
- A dict of vectors where the key is the name of the component [‘real’, ‘imag’, ‘freq’, ‘cratio’, ‘nat_freq’] and the value is a list of components for each mode. 
 - Example - eigenInfo = model.simulate(type="LINEAR", returnResults=True) print(eigenInfo['freq']) # mode 0 mode 1 mode 2 mode 3 mode 4 mode 5 >> (1591.5494309, 1591.5494309, 1591.54989555, 5032.92486205, 5032.9448705, 5032.928844) 
 - reset(restart=True)#
- Reset the model. Subsequent simulation commands will start at time = 0. 
 - runAllSimulationEvents()#
- Run all the valid SimulationEvent objects sequentially. 
 - save_model(file)#
- Saves a snapshot of the model. - Parameters
- file – A string corresponding to the file being created on your filesystem. The file is created by the pickle module. 
 
 - simulate(type='DYNAMICS', end=None, dtout=None, duration=None, steps=None, dsa=None, start=None, print_increment=None, constraint_tol=None, implicit_diff_tol=None, onOutputStep=None, returnResults=False, output='on', validate=True, active_contact_iteration=False, numThread=- 99999, acusolve_cosim=False, save_increment=None, save_inc_overwrite=False, store=False, **kwds)#
- Sends the model to the solver and runs the simulation. - Parameters
- type (Enum) – - The type of simulation. Valid choices are: - ”ASSEMBLY” 
- ”DYNAMICS” 
- ”TRANSIENT” 
- ”KINEMATICS” 
- ”STATICS” 
- ”FREQUENCYRESPONSE” 
- ”LINEAR” 
 
- end (float) – The end time of the analysis. 
- dtout (float) – The print interval. 
- duration (float) – The duration of the analysis. 
- steps (int) – The number of output steps to take between start and end. 
- dsa (Enum) – - The type of design sensitivity analysis. Valid choices are: - ”NONE” 
- ”AUTO” 
- ”DIRECT” 
- ”ADJOINT” 
- ”FD” 
- ”FD_SERIAL” 
 
- start (float) – The start time of the analysis. 
- print_increment (float) – The frequency of output in terms of the integrator steps that have been taken. 
- constraint_tol (float) – The tolerance on all algebraic constraint equations that the corrector must satisfy at convergence. 
- implicit_diff_tol (float) – Modifies the accuracy to which implicit differential equations are to be satisfied. 
- onOutputStep (callable function) – Supply a callable UPOST function that you want to be called at every output step. 
- returnResults (bool) – Specifies if run data will be returned to the caller. 
- output (Enum) – - Specifies protocol of standard output. Valid choices are: - ”on” 
- ”off” 
- ”fileonly” 
 
- validate (bool) – Specifies if the model will be validated before submission (default True). 
- numThread (int) – Specifies the number of threads for Open MP multithreaded contact simulation. 
- active_contact_iteration (bool) – Specifies whether the contact residual is being updated during the corrector step of the implicit solver and an analytical Jacobian is provided or not. A value of True means that the residual is being updated. 
- acusolve_cosim (bool) – Specifies if this simulation is a MotionSolve-AcuSolve co-simulation. 
- save_increment (int) – Dumps the XML file every save_increment multiple of print interval. 
- save_inc_overwrite (bool) – Overwrite the XML file each time or create a new one every save_increment with time stamp added to the file name. 
- store (bool) – Stores the simulation results in a list on the model. 
 
- Returns
- SimulationResults
- Output states for Bodies, Requests and Rvs. 
 
 
 - simulate_frequencyResponse(start, end, frequency_input, increment_type, steps, validate=False, returnResults=False, output='on')#
- Performs a frequency response analysis of the model - Parameters
- start (float) – The start frequency of the analysis. 
- end (float) – The end frequency of the analysis. 
- frequency_input (list(Reference)) – Select one or more frequency excitations defined in the model. 
- increment_type (Enum) – - The increment type for the Frequency Response Simulation. Valid choices are: - ”LOG” 
- ”LINEAR” 
 
- onOutputStep (callable function) – Supply a callable UPOST function that you want to be called at every output step. 
- returnResults (bool) – Specifies if run data will be returned to the caller. 
- output (Enum) – - Specifies protocol of standard output. Valid choices are: - ”on” 
- ”off” 
- ”fileonly” 
 
- steps (int) – The number of output steps to take between start and end. 
 
 
 - verify(validate=True, **kwds)#
- Sends the model to solver and performs a verification analysis. Validation of the model can be optionally skipped. - Parameters
- validate (bool) – Specifies if model validation is to be performed. 
- Returns
- count (int)
- Total number of kinematic independent coordinates computed by MotionSolve.