With only a few exceptions, all analysis entities are supported in SimSolid. However, there are instances where mapping may be
            ambiguous. Any items that cannot be reapplied will be marked in red in the project
                tree.All red entities must be resolved before the new analysis can be started.
                For connections and contact conditions, SimSolid will
                use automatic settings to reapply missing connections.
        - 
                Review SimSolid automatic connection/contact
                    condition resolution settings:
                
                    - Double-click on the desired connection/contact condition to
                        edit.
 
                    - Right-click on the desired connection/contact condition and choose
                            Accept contact condition(s) in red to accept
                        SimSolid's resolution.
 
                
             
- 
                For boundary conditions in red, double-click to open the definition
                    dialog.
            
 
- 
                Reselect the missing location (face, edge, spot, or other).
            
 
- 
                Click OK.
                
The red will be removed. You can now begin the analysis.