Combines multiple line connectors to a single line connector.
    Syntax
      
      
        *CE_ConnectorLineCombine
        mark_id entity_type entity_mark_id entity_list_id ce_style num_links
          link_entity_type link_mark_id string_array number_of_strings
      
    
    Type
      
      
        HyperMesh Tcl Modify Command
      
    
    Description
      
      Combines multiple line connectors to a single line connector.  In addition, the internal
        lines (within the connectors) are merged into a single internal line.
    
    
        Inputs
      
      
      
        
          - mark_id
- The ID of the mark of connectors.  Valid values are 1 and 2.
- entity_type
- The entity type that specifies the location to create connectors. Valid values are
            lines.
- entity_mark_id
- The ID of the mark containing the entities.  Valid values are 1 and 2.  If specified,
            set entity_list_id as 0.
- entity_list_id
- The ID of the list containing the entities.  Valid values are 1 and 2.  If specified,
            set entity_mark_id as 0.
- ce_style
- The style of connectors to create. Valid values are apply_mass, area, bolt, seam, and
            spot.
- num_links
- The number of links to use.
- link_entity_type
- The type of entity to create links for. Valid values are:
- comps (for spot, bolt, seam, area or apply_mass)
- elems (for spot or apply_mass)
- nodes (for spot or apply_mass)
- surfs (for spot, seam or area)
- tags (for spot or apply_mass)
- link_mark_id
- The ID of the mark of link entities.  Valid values are 1 and 2.
- string_array
- The string array ID that contains the additional input parameters. The string array is
            created using the *createstringarray command. This should always be
            set to 1. 
- Strings are indicated using the format "name=value". Valid strings are:
              
                - area_mesh_size=<value>
- The mesh size for area connectors when entity_type is surfs.
                  Default 10.0.
- area_mesh_type=<value>
- The mesh type for area connectors when entity_type is
                  surfs.
- 0 - Trias
- 1 - Quads
- 2 - Mixed
- 3 - Right trias
- area_offset=<value>
- Offset area connectors created from node or line lists from the selected
                  location by this value. Default 0.0.
- area_width=<value>
- Width of area connectors created from node or line lists. Default 1.0.
- line_combine_option=<value>
- The combine option for combining the two or more line
                    connectors:combine_smooth – Combines lines/connector with smooth
                    curve combine_straight – Combines lines/connectors with straight
                    curve combine_midline – Combines two lines/connectors as one midline
                    connector 
- line_density=<value>
- The density for spot or seam connectors on lines. Default 0.0.
- line_offset=<value>
- Offset value from the ends of the line for spot or seam connectors on lines.
                  Default 0.0.
- line_offset_flag=<value>
- 0 - Do not offset connectors (default)
- 1 - Offset connectors
- line_spacing=<value>
- The spacing for spot or seam connectors on lines.  Default 1.0.
- link_elems_geom=<value>
- Specifies whether to connect elems (default) or geom.
- link_rule=<value>
- Specifies the link rule. Valid values are now, at_fe_realize or none
                  (default).
- relink_rule=<value>
- Specifies the relink rule. Valid values are id, name or none (default).
- seam_area_group=<value>
- Flag for seam or area connector grouping:
- 0 - No (default)
- 1 - Yes
- tol=<value>
- Add entities as links only within this distance of the specified location.
                  Default 0.0.
- tol_flag=<value>
- Flag for seam or area connector grouping:
- 0 - Do not use tol (default)
- 1 - Use tol
 
- number_of_strings
- Integer indicating the size (number of strings) in the string array created using
              *createstringarray.
Examples
      
      To combine spot line connectors 1 and 2 , lines 3 and 4, and components links 1, 2, 3 and 4
        with combine_smooth
        option:
*createmark connectors 1 1 2
*createmark lines 1 3 4
*createmark comps 2 3 4
*createstringarray 9 "link_elems_geom=elems" "link_rule=now" "relink_rule=none" "tol_flag=1" "tol=99.0" "line_density=0" "line_spacing=5.000000" "line_offset=0.000000" "line_combine_option=combine_smooth"
*CE_ConnectorLineCombine 1 lines 1 1 spot 2 comps 2 1 9
Errors
      
      Incorrect usage results in a 
Tcl error. To detect
        errors, you can use the 
catch
        command:
if { [ catch {command_name...} ] } {
   # Handle error
}