*CE_DetailSetTripleByMark
Sets a triple connector detail for a mark of connectors.
Syntax
*CE_DetailSetTripleByMark mark_id detail_name triple_value1 triple_value2 triple_value3 reserved force_storage
Type
HyperMesh Tcl Modify Command
Description
Sets a triple connector detail for a mark of connectors.
Inputs
- mark_id
- The ID of mark containing the connectors to update. Valid values are 1 and 2.
- detail_name
- The name of the standard triple detail, or user-defined triple detail, to update. See *CE_DetailSetTriple for valid details.
- triple_value1
- The first triple value to update for the detail.
- triple_value2
- The second triple value to update for the detail.
- triple_value3
- The third triple value to update for the detail.
- reserved
- Reserved for future use. Must be set to 0.
- force_storage
- 0 - Do not store user-defined detail.
Examples
*createmark connectors 1 1 2 3
*CE_DetailSetTripleByMark 1 ce_ijk 0.0 1.0 0.0 0 0
Errors
if { [ catch {command_name...} ] } {
# Handle error
}